Almost every inquiry we receive opens the same way: we cut 6 mm stainless, what power do we need? The honest answer is that thickness only decides the floor — it does not decide the number. Two shops cutting the same 6 mm stainless can legitimately need 3 kW and 6 kW, and the difference is in the second question nobody asks: how many hours a day, and how fast does the part have to come off the table.
What power actually buys you
A fiber laser does not get "more accurate" with power. It gets faster at a given thickness, and able to cut thicker material at a workable speed. Everything else — accuracy, edge quality, nesting — is the same machine at 3 kW and at 12 kW.
So the buying question is really a production question: how many metres of cut do you need per shift, and what is the thickest material you cut every week (not once a quarter)?
| Power | Mild steel | Stainless | Aluminium |
|---|---|---|---|
| 1.5 kW | 8 mm | 4 mm | 3 mm |
| 3 kW | 12 mm | 6 mm | 6 mm |
| 6 kW | 20 mm | 12 mm | 12 mm |
| 12 kW | 25 mm | 20 mm | 20 mm |
Those are continuous-production numbers with the right assist gas — oxygen for mild steel, high-pressure nitrogen for stainless and aluminium. A 3 kW machine will pierce 15 mm mild steel if you are patient, but nobody runs a job shop that way.
The speed curve is not linear
Doubling power does not double speed, and this is where the money argument lives. Cutting 3 mm stainless, a 6 kW source runs roughly twice as fast as a 3 kW source. Going from 6 kW to 12 kW adds about 50–60% on the same material, not 100%.
On thin sheet the gain is often limited by the machine's acceleration, not the laser. If your work is 1–3 mm, a 12 kW source will spend most of its time waiting for the gantry. That is the single most common overbuying mistake we see.
Where 6 kW is the right answer
For a mixed job shop — 1 mm brackets one day, 10 mm flanges the next — 6 kW is the practical sweet spot. It covers up to 20 mm mild steel and 12 mm stainless at production speed, it leaves headroom for aluminium, and it does not demand a 400 A service or a chiller the size of a small car.
When 12 kW pays for itself
Three situations:
- Thick plate as the core business. 16–25 mm structural steel, day in, day out.
- Replacing two older machines. One 12 kW machine replacing a 4 kW and a 6 kW often clears floor space and labour at the same output.
- Stainless with nitrogen. Above 10 mm, the difference between 6 and 12 kW is the difference between a clean edge and a second operation.
The costs that scale with power
- Electrical supply. A 6 kW machine draws roughly 22–25 kW at the wall with the chiller; a 12 kW machine draws around 45 kW. Check your transformer before you check the price list.
- Chiller and floor space. Bigger source, bigger chiller, more clearance behind the machine.
- Assist gas. Nitrogen consumption on stainless rises with thickness and speed — often the largest running cost after electricity.
- Consumables. Protective lenses and nozzles cost roughly the same per hour regardless of power. This is the one line item that does not scale.
A forty-minute way to decide
Send three samples of the material you actually buy, at three thicknesses: your thinnest, your most common, and your thickest. Ask for a timed cut at two power levels and a cost-per-part figure, not a cost-per-metre figure. The power level that wins on cost per finished part is the one to buy — and it is frequently one step lower than the table suggests.
Rule of thumb
Buy one step above the thickness you cut every week — not the thickness you cut twice a year. A machine that is occasionally slow on an unusual job is cheaper than a machine that is permanently oversized, over-chilled and over-wired for the work it actually does.
If you want a second opinion on a specific material mix, send us the thickness list and the daily output. We will come back with two or three configurations and the reasoning behind each, including the one we think you should not buy.